Carel's EV2 , a leap in effective design and increased efficiency

11/26/2016

2 Comments

 
The flexibility of technology see's no limits.
​


Carel's EEV driver systems have a lot going for them, Here below the EVD series with something very different.
We have fitted two Carel E2V electronic linear pulse valves which operate a common base load in a complimentary arrangement.
The unit here is between 1800 to 2000 W refrigeration capacity with a 6K evaporator design working at -4 saturated evaporation temperature based on a 2.c room temperature. You can have one larger EEV serving the load but in this case we have used two smaller EEV units to give us a combined total capacity. This feature is known as "complimentary" mode where they open and close together in a parallel arrangement driven by the common driver signal , no need for a second input at the controller. You cant do this with all EEV arrangements but it does work and it works very well. We set them into a Y-junction with equidistant lines (both the same size) into a larger diameter feed pipe to the indoor coil. We did this to test it out and see how it all works.
Funny enough the EEV's can also be set up to work as an opposing arrangement where one will open and the other will close in unison equal steps. (of course im not sure where I would use that)
Now , The controller has it all and more, It even has built in wiring schematics in the interface display on how to wire the components such as the EEV, transducer and NTC probe and where. great if you forgot your installation manual. :D
I want to show you just how accurate these are, we are maintaining 5K with no load but getting from 75 to 80% relative humidity as per the expected refrigeration evaporator differences using a much lower TD than an air-conditioner. I have fitted a humidity meter in the cabinet.
No need for an EPR ,(on conventional coolroom design) the coil is saturated constantly,providing maximum efficiency ,no pressure drop from hunting through a conventional thermostatic expansion valve when the superheat and load is low. In that case the evaporator temperature difference widens temporarily lowering the relative humidity and drying out your high water content food products. We also fitted a speed controller to govern a high ambient 46.c condenser. This unit also Carel can work local or feedback to host PCo2 through network control.
You can see just how easy these are to use. Controls ready engineered to work local or by network. Another good feature is that a local digital input (switch) can be fitted to drive the EEV's closed which could be used as a pump down arrangement similar to a solenoid valve. We have one fitted to our electrical box.
2 Comments
Darren Dwyer
11/27/2016 07:31:22 am

We have install about 12 of these this year. this is the way forward , like many carel products they have a reset to defaults feature , if you get stuck or someone has fiddled with your config.

Reply
Dennis Kenworthy
11/27/2016 08:48:02 am

Thanks Darren.

I like the inbuilt wiring schematic to assist a technician in setting it up correctly. These are part of the home scroll menus.
Its good thought that embeds this and sometimes people these days work better from a screen than a book.

Reply

Your comment will be posted after it is approved.


Leave a Reply.

    Picture
    Please note:

    All comments require moderation before they will be posted. This may take up to 24hrs, thankyou for your patience. 

    Archives

    August 2017
    January 2017
    November 2016
    October 2016
    September 2016
    August 2016
    July 2016

    Categories

    All
    Compressor
    Danfoss
    EEV
    Enthalpy
    Expansion
    IGBT
    Inverter
    Iphone
    Orifice
    Pcb
    PTC
    Relay
    Split System
    Testo
    Venturi Effect

    RSS Feed

Powered by Create your own unique website with customizable templates.